Bolls ApS

EMC TEST

EMC test

At Bolls ApS, we offer to perform EMC tests in our own well-equipped EMC laboratory.

The tests can be performed either with or without the customer's presence.

The test results are delivered in a comprehensive EMC test report unless otherwise agreed. Our reports are often accepted across most of the world on an equal footing with accredited reports, which are usually much more expensive.

Should a product fail one or more tests, we at Bolls have extensive experience in troubleshooting and suggesting makeable corrections. It is recommended that the designer is present at the test so that the greatest possible knowledge of any problems is transferred to the customer.

Among other things, we can offer the following tests:

  • Emission 30 MHz - 7 GHz (18 GHz) in a 3 meter screen space (as well as indoor 3 m free field measuring space)
  • Magnetic field emission   25 Hz - 30 MHz
  • Cord-borne emissions   9 KHz - 300 MHz
  • EN 61000-3-2   Harmonic currents
  • EN 61000-3-3   Flicker
  • EN 61000-4-2   ESD
  • EN 61000-4-3   RF field up to 6 GHz
  • EN 61000-4-4   Burst
  • EN 61000-4-5 Surge
  • EN 61000-4-6   RF cord-borne
  • EN 61000-4-8   Magnetic field
  • EN 61000-4-9   Pulse magnetic field
  • EN 61000-4-11   Voltage varations and dips
  • EN 61000-4-13   Immunity to mains signalling at a.c. power port
  • EN 61000-4-14   Voltage fluctuation immunity test
  • EN 61000-4-17   Ripple on d.c. input power port immunity test
  • EN 61000-4-28   Frequency variation
  • EN 61000-4-29 Dips on dc
  • ISO 7637 automotive equipment
  • Maritime equipment   (EN 60945, E10, etc.)
  • Train equipment
  • Aircraft equipment (only some tests after DO 160 etc.)

The following sources of supply may be used;

50 - 250 Vac, 16.7 - 400 Hz, supply max. 16A 1 phase 0 - 400 Vac, 50 Hz, 16A/phase 3 phase (32A for certain tests) 0-60Vdc up to 60A

All common product family standards are covered (EN 55013, -14, -15, -20, -22, -24) + a wide range of other special tests.

Call and hear more.